Apc Rack Pdu 2G, Metered, Zerou, 22.0Kw(32A) 17.3Kw(24A), 230V,(30) C13 & (12) C19 [AP8886]

Model: AP8886 / Item No: 382186

Apc Rack Pdu 2G, Metered, Zerou, 22.0Kw(32A) 17.3Kw(24A), 230V,(30) C13 & (12) C19 [AP8886]

More Views


APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.


Metered Rack PDU Features & Benefits


Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.


Product Distribution




Nominal Output Voltage
Maximum Total Current Draw per Phase
Output Connections
(30) IEC 320 C13 IEC 320 C13
(12) IEC 320 C19 IEC 320 C19
Overload Protection


Nominal Input Voltage
400V 3PH
Input Frequency
50/60 Hz
Input Connections
IEC 309 32A 3P+N+E  
Cord Length
1.83 meters
Maximum Line Current per phase
Maximum Input Current per phase
Load Capacity
22 kVA


Net Weight
8.72 KG
Maximum Height
1829.00 mm
Maximum Width
56.00 mm
Maximum Depth
51.00 mm
Shipping Weight
11.55 KG
Shipping Height
2050.00 mm
Shipping Width
170.00 mm
Shipping Depth
112.00 mm


Operating Environment
0 - 55 °C
Operating Relative Humidity
5 - 95%
Operating Elevation
0-3000 meters
Storage Temperature
-25 - 65 °C
Storage Relative Humidity
5 - 95%
Storage Elevation
0-15000 meters


Regulatory Approvals
EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, VCCI Class A, VDE
Standard Warranty
2 years repair or replace

Sustainable Offer Status

REACH: Contains No SVHCs
Battery Directive
Battery Notes
Contains Lithium Coin Cell
*Except where noted, all prices are Estimated Resale Price (ERP) - With Tax/VAT. Pricing in other locations and sites may vary.


Shipping Calculator

Skycomp Technology uses the best carriers in the business to make sure your order gets to you on time.
Australia Post eParcel 
eParcel generally takes 2-10 business days to be delivered depending on final destination.
We recommend you use this service for PO Box or if you believe your delivery address will be unattended as you will be able to collect this from your local Post Office. 

Australia eParcel Express
eParcel Express generally takes 1-3 business days to be delivered depending on final destination.
We recommend you use this service for PO Box or if you believe your delivery address will be unattended as you will be able to collect this from your local Post Office.

Other prefered partner
• Local Express:Delivered in 1-2 Business Days 
• Nationwide Delivery: 1-4 Business Days* 
• Nationwide Express: Next Business Day* 
*Allow extra days for regional areas 
All orders will be shipped from our Australian (NSW/QLD/VIC/WA) warehouses. More than 95% order are shipped via Australia Post E-Parcel and some from our preferred Partner listed below:

Following are the contact details of the freight companies we use:


Ph: 02-92800583 
Usually 24 hours after placing your order.

Your requirements will be our passion

For IMMEDIATE customer service assistance or help with an order please

  • Reload captcha

* Required Fields

Have you considered this?