(02) 90112078 | 
Contact us |  
COMPUTER HARDWAREPC & NOTEBOOKSSOFTWAREPRINTERS & SCANNERSSERVERSNETWORKINGELECTRONICS

Aten Ec1000 Nrgence Energy Box Over Ip

Model: EC1000 / Item No: 311493
Call us for availability

Add to Cart
Add to Wishlist
OR

Aten Ec1000 Nrgence Energy Box Over Ip

More Views

Details

Description: Aten EC1000 – NRGence Energy Box over IP The EC1000 Energy Box is the latest evolution of NRGence™ – ATEN's energy intelligence solutions. It is the intelligent, cost effective solution to monitor ATEN's Energy PDUs – to ensure safe and effective energy-saving power management. The EC1000 Energy Box has four Energy Sensor ports to connect to four Energy PDU modules and four Environment Sensor ports for external sensors to monitor environmental conditions. Each environmental sensor can provide measured readings of temperature, humidity, and differential pressure from separate areas of a data room, giving a wide range of monitoring and protection you need. The Energy Box allows power and environmental data to be monitored and displayed at the rack or remotely for easy viewing and maintenance. The Energy Box is a standalone unit with Over IP monitoring that is controlled by Web GUI or ATEN´s eco Sensors software. The EC1000 Energy Box features real-time status, system logs, threshold alerts, and event notifications. The EC1000 logs power and environmental conditions according to customizable minimum/maximum thresholds set for electrical current, temperature, humidity, and differential pressure. Remote monitoring offers secure access with 128bits SSL encryption, and customizable account policies for user management. Remote authentication supports RADIUS and additional management interfaces including HTTP, HTTPS, and SNMPv1&v2&v3 (Read, Write, Trap). Event notifications can be monitored via Syslog/SMTP/SNMP trap and audible alarms for real–time local and remote alerting. When used in conjunction with ATEN´s Energy PDUs* and eco Sensors Energy Management Software*, the EC1000 allows you to conveniently upgrade your cabinet with remote energy management functionality to make your server room go green quickly and cost-effectively.   Features: Operation Space saving 1U rack mounting with front and rear mounting 4 RJ-45 Energy Sensor Ports to monitor four Energy PDU currents (0A to 32A per port) 4 RJ-11 Environment Sensor Ports to monitor temperature, humidity, and differential pressure* Maximum Amperage Monitor 32A@100V~240V (Energy Box) 3 digit 7 segment front panel LED displays current/sensor/IP address information Threshold monitoring for: 1. Current 2. Temperature* 3. Humidity* 4. Differential pressure* Threshold alerting through: 1.  Local: audible alarm and LED lights 2.  Remote: SMTP/SNMP trap/Syslog Management Front panel LED indicators for current, temperature*, humidity*, differential pressure*, and IP address information at the Energy Box Remote real-time current, temperature*, humidity*, and differential pressure* monitoring and management Management through eco Sensors Energy Management Software or 3r party SNMP manager Supports name assignment for individual Energy PDUs Event Logging – 128 line event log Syslog support F/W upgradable Remote Access Remote management via TCP/IP using built in 10/100Mbps Ethernet port Management via built in browser based GUI Network Interfaces: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping Supports SNMP Manager V1, V2, V3 Security Strong security features include password protection and advanced encryption technologies – utilizing 128 bit SSL RADIUS authorization and authentication * Requires external sensorsSpecifications: Energy PDU Connections 4 Port Selection Pushbutton Connectors Energy Sensor 4 x RJ-45 Female Environment Sensor 4 x RJ-11 Female Power 1 x DC Jack LAN 1 x RJ-45 Female Switches Reset 1 x Semi-recessed Pushbutton Selection 1 x Selection Pushbutton LEDs PDU Status 4 (Orange) Sensor Status 4 (Green) Energy/Environment/IP 3 (Green) Selection 1 digit 7-segment (Orange) Current/Sensor/IP Address 3 digit 7-segment (Orange) Power 1 (Blue) LAN 10M/ 100Mbps 1 (Orange/Green) Link 1 (Green) Monitoring Range 100–240V; 50/60Hz; 0A to 32A (per port) LED Display Resolution 0.1A Precision: ±0.1A@0 ~ 1A, ±1% 1A Power Consumption DC 5.3 V Environment Operating Temp. 0-50°C Storage Temp. -20-60°C Humidity 0 - 80% RH, Non-condensing Physical Properties Housing Metal Weight 0.59 kg Dimensions ( L x W x H ) 20.00 x 7.59 x 4.20 cm   Package Contents 1 x EC1000 Energy Box 1 x Power Adapter 1 x Mounting Kit 4 x RJ-45 Cables 1 x CD ROM (Manual, eco Sensors Software) 1 x User Instructions

Details

Shipping Calculator

 
 
Skycomp Technology uses the best carriers in the business to make sure your order gets to you on time.
 
Australia Post eParcel 
eParcel generally takes 2-10 business days to be delivered depending on final destination.
We recommend you use this service for PO Box or if you believe your delivery address will be unattended as you will be able to collect this from your local Post Office. 

Australia eParcel Express
eParcel Express generally takes 1-3 business days to be delivered depending on final destination.
We recommend you use this service for PO Box or if you believe your delivery address will be unattended as you will be able to collect this from your local Post Office.

Other prefered partner
• Local Express:Delivered in 1-2 Business Days 
• Nationwide Delivery: 1-4 Business Days* 
• Nationwide Express: Next Business Day* 
*Allow extra days for regional areas 
 
 
All orders will be shipped from our Australian (NSW/QLD/VIC/WA) warehouses. More than 95% order are shipped via Australia Post E-Parcel and some from our preferred Partner listed below:
 

Following are the contact details of the freight companies we use:

 

IN STORE PICK UP IN SYDNEY
Ph: 02-92800583 
Usually 24 hours after placing your order.

Details

See manufacturer website for warranty terms.
Aten -

Warranty: 12 months

Your requirements will be our passion

For IMMEDIATE customer service assistance or help with an order please


  • Reload captcha

* Required Fields

Have you considered this?