General
Location Category Indoor
Dimensions - Including hinges (H x W x D, mm) 50 x 155 x 150
Weight (g) 500
Warranty 12 months
 
Electrical
Input voltage (Uc) 200-250VAC 1 Phase
Max Continuous Voltage (Mcov) 285VAC L-N
Number of ports 2 Port
Method of mounting Portable
Service type TT, TN, TN C-S or any 1 phase system with a grounded neutral. This unit must not be connected to an ungrounded system.
Temporary overvoltage - TOV 300VAC L-N, 15 mins
Test Classification Class II
Energy Absorption rating - per mode (joules) Primary Protection L-N = 370J
Primary Common Mode protection L-E & N-E = 480J
Secondary protection L-N = 225J
Secondary Common Mode protection L-E & N-E = 480J
Aggregate rating = 1,555J
Current rating - continuous 16A
Test Classification Class III (IEC 61643-1), Category A (ANSI/IEEE C62.41)
Recommended max. overcurrent protection 16A
Residual current <0.5 mA
Protection modes Line-Neutral, Line-Earth, Neutral-Earth
In 8/20us (Line-Neutral) Nominal surge life 10kA x 20 hits
In 8/20us (Line-Earth) Nominal surge life 3kA x 20 hits
In 8/20us (Neutral-Earth) Nominal surge life 3kA x 20 hits
Ismax 8/20us (Line-Neutral) Max surge level 20kA
Ismax 8/20us (Line-Earth) Max surge level 10kA
Ismax 8/20us (Neutral-Earth) Max surge level 10kA
Filter attenuation 40dB nominal above 1MHz
Initial clamp voltage (Line-Neutral) 560V
Initial clamp voltage (Line-Earth) 680V
Initial clamp voltage (Neutral-Earth) 680V
Residual voltage (Vpl) (Line-Neutral) (Let through voltage) <1100 (3kA, 8/20uS)
Residual voltage (Vpl) (Line-Earth) (Let through voltage) <1400 (3kA, 8/20uS)
Residual voltage (Vpl) (Neutral-Earth) (Let through voltage) <1400 (3kA, 8/20uS)
Internal protection (fusing) Thermal fusing on primary line-connected MOVs
Terminations IEC 320-C20 16A input x 1,, IEC 320-C19 16A output x 1
 
Communications
Alarms/indicators Includes status indicators, dry contact alarm relay output (normally-closed with power applied and all SPD’s at 100% capacity). Contact rating 250Vac/32Vdc, 5A, alarm under-voltage cut off 180Vac.
   
Environmental & Standards
Enclosure rating IP42
Standards. Designed in accordance with : IEC61643-1:2005, IEC610006-1,2,3,4 ANSI/IEEE C62.41, AS/NZS1768, AS/NZS3000:2007, AS3100
Environment -10 to 65°C, 10 to 90%RH (non-condensing)
   
Notes
Specifications are subject to change without notice

Details

Shipping Calculator

 
 
Skycomp Technology uses the best carriers in the business to make sure your order gets to you on time.
 
Australia Post eParcel 
eParcel generally takes 2-10 business days to be delivered depending on final destination.
We recommend you use this service for PO Box or if you believe your delivery address will be unattended as you will be able to collect this from your local Post Office. 

Australia eParcel Express
eParcel Express generally takes 1-3 business days to be delivered depending on final destination.
We recommend you use this service for PO Box or if you believe your delivery address will be unattended as you will be able to collect this from your local Post Office.

Other prefered partner
• Local Express:Delivered in 1-2 Business Days 
• Nationwide Delivery: 1-4 Business Days* 
• Nationwide Express: Next Business Day* 
*Allow extra days for regional areas 
 
 
All orders will be shipped from our Australian (NSW/QLD/VIC/WA) warehouses. More than 95% order are shipped via Australia Post E-Parcel and some from our preferred Partner listed below:
 

Following are the contact details of the freight companies we use:

 

IN STORE PICK UP IN SYDNEY
Ph: 02-92800583 
Usually 24 hours after placing your order.

Your requirements will be our passion

For IMMEDIATE customer service assistance or help with an order please


  • Reload captcha

* Required Fields

Have you considered this?