TST ESR-104 SAS/SATA 1U Case, 4 hotswap HDD support, 560W Fixed Power Supply included slide rail, all cable. Supports SSI EEB 3.5, CEB 1.1 or AMD Dual Opteron compliant server boards. 2 X USB ports, 1 X DB9 port, drive bay: Internal slim FDD x 1, Internal slim CD x 1, Internal slim 2.5" x 1 ( 3 maximum ), Hotswap Bay x 4
Features and Benefits
Supports SSI EEB 3.5, CEB 1.1 or AMD Dual Opteron compliant server boards
Power MOSFET and pre-charge circuit for surge current protection on hard drive and backplane
Horizontal backplane design to allow maximum airflow for system cooling
Fan failure, over-temperature detection
3 years warranty on power supply
Other High Quality Components are backed by a lifetime warranty
Specification
Dimensions
1.75"(H) x 19"(W) x 28"(D)
Front Access Connector
2 X USB ports, 1 X DB9 port
Front Access switch
Power On/Off, Reset, Alarm Reset
Front Panel Indicators
Power On, HDD Activity, Fan failure, Overheat warning, LANs
Hot swap drive indicators
Power On, HDD Activity, HDD failure
Power Supply
500W EPS12V power supply
Power Supply Options
up to 700W Fixed, Redundant, high efficiency 80+
System Board
Up to 12x13 E-ATX, ATX, EEB 3.5, CEB 1.1 compliant
Drive Bay
Internal slim FDD x 1
Internal slim CD x 1
Internal slim 2.5" x 1 ( 3 maximum )
Hotswap Bay x 4
Data Backplane
Serial ATA PTP
Serial ATA Multilane
Ultra 320 SCA
Serial Attached SCSI
Included Data cableYes
Included slide railYes
System Monitoring
Fan / over heat / power supply fault detection
Thermal
Intel Validated Pass Xeon 3.73Ghz 1066Mhz
SATA backplane Specification
11. A power MOSFET to provide disk spin-up control 2. A pre-charge circuit for surge current protection when a disk is plugged in to protect the hard-disk drive and the backplane. 3. LED: Blue ON = HDD present; Blue Blinking = Drive activity; Red=Drive failure 4. A 4x2 header for Drive activity and Drive failure LED signal input 5. Single DC input to provide better cable management 6. Option for SATA PTP. SAS, multilane and miniSAS 7. Option support SAS expander
SCSI backplane Specification
1. A power MOSFET to provide disk spin-up control 2. A pre-charge circuit for surge current protection when a disk is plugged in to protect the hard-disk drive and the backplane. 3. LED: Blue ON = HDD present; Blue Blinking = Drive activity; Red=Drive failure 4. A 4x2 header for Drive activity and Drive failure LED signal input 5. Single DC input to provide better cable management 6. Piano Switch for easy SCSI ID setting 7. Two HD68 SCSI connectors for daisy chain if required
Technical Documentation
Technical Borchure
ESR-104.pdf
User Manual
ESR-104_manual_rev_1.pdf